User's Manual

Chengdu Ebyte Electronic Technology Co., Ltd E104-BT5032A User Manual
Copyright ©2012–2019Chengdu Ebyte Electronic Technology Co., Ltd
31
Disconnect all AT+DISCON
+OKsuccess
+ERR=[NUM]error
Parameter
handle(ASCII)
description
0~7
Disconnect specified connection
Remark
1 Take into effect immediately.
2 As slave, only disconnect all is available
3 Disconnect all is available for master and slave mode
4 If handle specified connection is not connected, the module will return error;
5 For Handle please refer to 错误!未找到引用源。 multilink.
6.4.25 AT+DATDLY Data output delay
command respond
Query AT+DATDLY? +OK=[para]
Set
AT+DATDLY=[para]
+OKsuccess
+ERR=[NUM]error
Parameter
paraASCII
description
0 close
1 enable(default)
Remarks
1 Take into effect immediately, save when power off
2 Turn on the output delay, the maximum packet size does not exceed 244 bytes;
3 Turn on the output delay. If the air packet input is too fast, the entire packet will be lost.
6.4.26 AT+MAC local MAC address
command respond
Query AT+MAC? +OK=[para]
Parameter
paraHEX:MAC address
For exampleF0E1D2C3B4A5
Remarks Take into effect immediately, save when power off
For example
CommandAT+MAC?
Return2B 4F 4B 3D FE 30 EE 50 35 DA
Descriptionlocal MAC is FE 30 EE 50 35 DA
6.4.27 AT+PEERMAC connect to device MAC
command respond