Inquire AT+IPWR? +OK=[para]
Set AT+ IPWR =[para]
+OK:success
+ERR=[NUM]:error
Parameter
para(ACSII): -128~127
Default: 0
Remark
1. Take into effect immediately(if advertising is not enabled, or it is connected, then take into effect next
time),save when power off;
2. Advertising available for slave only, other role can configurate;
6.4.21 AT+NAME advertise device name
command respond
Inquire AT+NAME? +OK=[para]
Set AT+NAME=[para]
+OK:success
+ERR=[NUM]:error
Set
(Do not save)
AT+NAME1=[para]
Parameter
para(HEX): advertise device name
device name is within 22 bytes
Default: E104-BT5032A
Remark
1、 Take into effect immediately, save when power off. AT+NAME1 does not save.
2、 Advertising available for slave only, other role can configurate
6.4.22 AT+CONPARAMS connection gap configuration
command respond
Inquire AT+CONPARAMS? +OK=[ intv],[ latency],[timeout]
Set
AT+ CONPARAMS =
[intv],[latency],[timeout]
+OK:success
+ERR=[NUM]:error
Parameter
[intv](ASCII) : connection gap,range,6~3200;
[latency] (ASCII) : slave delay. range,0~499
[timeout](ASCII): connection timeout, range,10~3200
Default:16,0,400
Remark
Take into effect immediately, save when power off
Note
1、 Connection timeout must be more than connection interval
2、 Timeout *4 > (1 + latency)* intv;
3、 Error parameter device will not save
4 、Only the default parameters of the connection parameters are set. After the setting is completed, it does
not affect the currently connected links.
5 、It is not recommended to set the connection parameters of the host too large. This will cause the