User's Manual

Chengdu Ebyte Electronic Technology Co., Ltd E104-BT5032A User Manual
Copyright ©2012–2019Chengdu Ebyte Electronic Technology Co., Ltd
29
Inquire AT+IPWR? +OK=[para]
Set AT+ IPWR =[para]
+OKsuccess
+ERR=[NUM]error
Parameter
para(ACSII) -128~127
Default: 0
Remark
1. Take into effect immediatelyif advertising is not enabled, or it is connected, then take into effect next
time),save when power off
2. Advertising available for slave only, other role can configurate
6.4.21 AT+NAME advertise device name
command respond
Inquire AT+NAME? +OK=[para]
Set AT+NAME=[para]
+OKsuccess
+ERR=[NUM]error
Set
Do not save
AT+NAME1=[para]
Parameter
para(HEX): advertise device name
device name is within 22 bytes
Default: E104-BT5032A
Remark
1 Take into effect immediately, save when power off. AT+NAME1 does not save.
2 Advertising available for slave only, other role can configurate
6.4.22 AT+CONPARAMS connection gap configuration
command respond
Inquire AT+CONPARAMS? +OK=[ intv],[ latency],[timeout]
Set
AT+ CONPARAMS =
[intv],[latency],[timeout]
+OKsuccess
+ERR=[NUM]error
Parameter
[intv]ASCII) : connection gaprange6~3200
[latency] (ASCII) : slave delay. range0~499
[timeout]ASCII: connection timeout range10~3200
Default160400
Remark
Take into effect immediately, save when power off
Note
1 Connection timeout must be more than connection interval
2 Timeout *4 > (1 + latency)* intv;
3 Error parameter device will not save
4 Only the default parameters of the connection parameters are set. After the setting is completed, it does
not affect the currently connected links.
5 It is not recommended to set the connection parameters of the host too large. This will cause the