6.4.17 AT+IBCNUUID iBeacon UUID command
command respond
Inquire AT+IBCNUUID? +OK=[para1]
Set AT+IBCNUUID=[para]
+OK:success
+ERR=[NUM]:error
Parameter
para(HEX):16 bit UUID
Remark
1、 Take into effect immediately(if advertising is not enabled, or it is connected, then take into effect
next time),save when power off;
2、 Advertising available for slave only, other role can configurate;
For example
Set iBeacon UUID:
“FDA50693A4E24FB1AFCFC6EB07647825”AT+IBCNUUID=FDA50693A4E24FB1AFCFC6EB07647
825
6.4.18 AT+MAJOR iBeacon Major Command
command respond
Inquire AT+MAJOR? +OK=[para]
Set AT+MAJOR=[para]
+OK:success
+ERR=[NUM]:error
Parameter
para(ACSII): 1~65535
Default: 513
Remark
1. Take into effect immediately(if advertising is not enabled, or it is connected, then take into effect next
time),save when power off;
2. Advertising available for slave only, other role can configurate;
6.4.19 AT+MINOR iBeacon Minor command
command respond
Inquire AT+Minor? +OK=[para]
Set AT+Minor=[para]
+OK:success
+ERR=[NUM]:error
Parameter
para(ACSII): 1~65535
Default: 1027
Remark
1. Take into effect immediately(if advertising is not enabled, or it is connected, then take into effect next
time),save when power off;
2. Advertising available for slave only, other role can configurate;
6.4.20 AT+IPWR modify ibeacon tx_power
command respond