User's Manual

Chengdu Ebyte Electronic Technology Co., Ltd E104-BT5032A User Manual
Copyright ©2012–2019Chengdu Ebyte Electronic Technology Co., Ltd
25
3
Multiple masters and multiple slaves coexist
Remark take into effect after reset and save when power off
6.4.8 AT+DEVMANUF modify manufacture name
command respond
Inquire AT+DEVMANUF? +OK=[para]
Set AT+DEVMANUF =[para]
+OKsuccess
+ERR=[NUM]error
Parameter
para(string): manufacture name
Default: CDEBYTE;
Remark
1 take into effect after reset and save when power off
2 string is up to 32bytes
6.4.9 AT+DEVSERIAL modify device serial
command respond
Inquire AT+DEVSERIAL? +OK=[para]
Set AT+ DEVSERIAL =[para]
+OKsuccess
+ERR=[NUM]error
Parameter
para(string): device serial
default:123456;
Remark
1 take into effect after reset and save when power off
2 string is up to 32bytes
6.4.10 AT+DEVMODEL modify device model
Command respond
Inquire AT+DEVMODEL? +OK=[para]
Set AT+ DEVMODEL =[para]
+OKsuccess
+ERR=[NUM]: error
Parameter
para(string): device model NO.
Default: E104-BT50
Remark
1 take into effect after reset and save when power off