User's Manual

Chengdu Ebyte Electronic Technology Co., Ltd E104-BT5032A User Manual
Copyright ©2012–2019Chengdu Ebyte Electronic Technology Co., Ltd
23
Parameter
paraASCII
Baud rate(bps)
0 1200
1 2400
2 4800
3 9600
4 14400
5 19200
6 28800
7 38400
8 57600
9 76800
10
115200default
11 230400
12 250000
13 460800
14 921600
Remark take into effect after reset
For example
AT+BAUD=10, baud rate is 115200
HEX:41,54,2B,42,41,55,44,3D,31,30
6.4.5 AT+PARI parity
Command respond
Inquire AT+PARI? +OK=[para]
Set AT+PARI=[para]
+OKsuccess
+ERR=[NUM]error
Parameter
para(ASCII) Description
0
Nonedefault
1 Even
Remark take into effect after reset and save when power off
For example AT+PARI=0
6.4.6 AT+HWFC flow control
Command Respond
Inquire AT+HWFC? +OK=[para]
Set AT+ HWFC =[para]
+OKsuccess
+ERR=[NUM]error