User's Manual

Chengdu Ebyte Electronic Technology Co., Ltd E104-BT5032A User Manual
Copyright ©2012–2019Chengdu Ebyte Electronic Technology Co., Ltd
13
6 DISC Input
Connection pin
disconnected
Internal pull up. Valid in
falling edge
7 LINK
3
Output Link status
Ble linklow level
No ble linkhigh level
8 DATA
4
Output Data indicator -
9 GND - Ground -
10 P0.02 - NC -
11 P0.03 - NC -
12 P0.04 - NC -
13 P0.05 - NC -
14 P0.06 - NC -
15 P0.07 - NC -
16 GND - Ground Ground
17 VCC - Power Power
18 RXD Input UART RX pin -
19 TXD Output UART TX pin -
20 RTS Output Flow control Internal pull up
21 CTS Input Flow control Internal pull up
22 P0.21/RST - Power reset Valid in low level
23 SWDCLK - - -
24 SWDIO - - -
5. Function
5.1 Roles
There are four roles: master, slave, observer, salve and master as one.
The master module/slave and master as one connects to other Ebyte Bluetooth models. Up to 4 slaves can be connected to it.
Transparent advertising and format transmission are available. Both manual and automatic connection are allowed.
The slave module connects to other Ebyte Bluetooth models, only one connection is allowed. Only transparent transmission is
available for slave.
The observer is only used to print information about the ble device around the module and cannot be connected.
Note: BLE is initiated by the master, and the slave responds. Where it is located manually, the automatic connection
function is only valid for the master and master-slave integration.
3
The internal level of the pin is self-latching. It internally pulls up for high level and pulls down for low level.
4
Same to 3.