User's Manual

Chengdu Ebyte Electronic Technology Co., Ltd E104-BT05 User Manual
Copyright ©20122019Chengdu Ebyte Electronic Technology Co.,Ltd
21
AT+RESTORE
+OK
None
Description: Be effective at once
5.33 Request/Authenticate Air configuration password
Command
Respond
Parameter
RequestAT+AUTH?
+OKsuccess
+ERR=[NUM]error
para6-byte password
HEXASCII
SetAT+AUTH =[para]
+OKsuccess
+ERR=[NUM]error
Description :
1. Password cannot be changed before authentication is successful.
2. The command is only used in air configuration
5.34 Update air configuration password
Command
Respond
Parameter
RequestAT+UPAUTH=[para]
+OK:success
+ERR=[NUM]error
para: 6-byte password
Description :
The configuration will take effect after entering the air next time, save when power off
5.35 Request/Set transmitting power
Command
Respond
Parameter
RequestAT+ PWR?
+OK=[para]
Para: 0~9 ASCII
0:+8dBm
1:+4dBm
2: 0dBm
3:-4dBm
4:-10dBm
5:-14dBm
6:-20dBm
7:-28dBm
8:-30dBm
9:-37dBm
SetAT+ PWR =[para]
+OKsuccess
+ERR=[NUM]error
Description: Be effective at once, save when power off
5.36 Request/Set sleep after disconnection
Command
Respond
Parameter