5.24 MAC Read/Set bonded MAC address
Command
Respond
Parameter
RequestAT+BONDMAC?
+OK=[para]
Para:MAC address HEX
ExampleF0E1D2C3B4A5
SetAT+BONDMAC=[para]
+OKsuccess
+ERR=[NUM]error
Description: be effective at once, save when power-off
For example, set the bound MAC to “313233343536”: AT+BONDMAC=123456
(123456 is ASCII, convert to hexadecimal is: 313233343536)
5.25 Request/Set MTU length
Command
Respond
Parameter
RequestAT+MTU?
+OK=[para]
Para: ASCII
01 stop bit
12 stop bit
SetAT+MTU=[para]
+OKsuccess
+ERR=[NUM]error
Description: Restart takes effect, save when power-off
5.26 Request/Set transparent transmission service UUID length
Command
Respond
Parameter
RequestAT+UUIDTYPE?
+OK=[para1]
Para1: 01 ASCII
02-byte UUID
116-byte UUID
SetAT+UUIDTYPE=[para1]
+OKsuccess
+ERR=[NUM]error
Description : Reconnection takes effect, save when power-off
5.27 Request/ Set Bluetooth service UUID
Command
Respond
Parameter
RequestAT+UUIDSVR?
+OK=[para2]
Para1: UUID value
HEX
SetAT+UUIDSVR=[para2]
+OKsuccess
+ERR=[NUM]error
Description: Reconnection takes effect, save when power-off, according to UUID length settings, saves in little endian mode
For example, set 2-byte UUID to “FFFO”41 54 2B 55 55 49 44 53 56 52 3D F0FF
For example,16-byte UUID “11223344556677889900AABBCCDDEEFF”