User's Manual
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT05 User Manual
Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co.,Ltd
16
5.10 Request/Set iBeacon UUID
Command
Respond
Parameter
Request:AT+IBCNUUID?
+OK=[para1]
Para1:16 位 UUID
HEX
Set:AT+IBCNUUID=[para1]
+OK:success
+ERR=[NUM]:error
Description: Be effective at once
Example:Set iBeacon UUID as “FDA50693A4E24FB1AFCFC6EB07647825”
41 54 2B 49 42 43 4E 55 55 49 44 3D FDA50693A4E24FB1AFCFC6EB07647825
5.11 Request/Set IBCTXPWR
Command
Respond
Parameter
Request:AT+IBCTXPWR?
+OK=[para1]
Para1:00H~FFH
HEX
Set:AT+ IBCTXPWR =[para1]
+OK:success
+ERR=[NUM]:error
Description:Be effective at once,save when power off,sent in hexadecimal
For example change to hex"31 32”: AT+IBCTXPWR =12(12 is ASCII, convert to hexadecimal is: 31 32)
5.12 Read/Set device name(save when power off)
Command
Respond
Parameter
Request:AT+NAME?
+OK=[para]
Para: broadcast device name,
HEX、ASCII
broadcast name not more than 22
bytes
Set:AT+NAME=[para]
+OK:success
+ERR=[NUM]:error
Description:The next broadcast will take effects,save when power off
For example, set to “E104-BT05”:AT+NAME=E104-BT05
5.13 Read/Set device name(Do not save when power off)
Command
Respond
Parameter
Request:AT+NAME1?
+OK=[para]
Para: broadcast device name ,
HEX、ASCII
broadcast name not more than 22
bytes
Set:AT+NAME1=[para]
+OK:success
+ERR=[NUM]:error
Description:The next broadcast will take effects,do not save when power off
For example, set to “E104-BT05”:AT+NAME1=E104-BT05