5.2 Read and configure baud rate
Command
Respond
Parameter
Request:AT+BAUD?
+OK=[para]
Para:0~8 ASCII
0=2400
1=4800
2=9600
3=19200
4=38400
5=57600
6=76800
7=115200
8=256000
SetAT+BAUD=[para]
+OKsuccess
+ERR=[NUM]error
Description: Restart takes effect, save when power off
5.3 Read and configure stop bits
Command
Respond
Parameter
RequestAT+STOPB?
+OK=[para]
Para:0,1 ASCII
01 stop bit
12 stop bit
SetAT+STOPB=[para]
+OKsuccess
+ERR=[NUM]error
Description: Restart takes effect, save when power off
5.4 Read/Set serial verification bits
Command
Respond
Parameter
RequestAT+PARI?
+OK=[para]
Para:0,1,2 ASCII
0No parity;
1Odd Parity;
2even parity;
SetAT+PARI=[para]
+OKsuccess
+ERR=[NUM]:error
Description: Restart takes effect, save when power off
5.5 Check current broadcasting status, turn on general broadcasting, IBeacon
broadcasting, turn off broadcasting
Command
Respond
Parameter
RequestAT+ADVEN?
+OK=[para]
Para:012 ASCII
0Turn off the broadcast
1General broadcasting
2iBeacon broadcast
SetAT+ADVEN=[para]
+OKsuccess
+ERR=[NUM]error