User's Manual
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT05 User Manual
Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co.,Ltd
14
5.2 Read and configure baud rate
Command
Respond
Parameter
Request:AT+BAUD?
+OK=[para]
Para:0~8 ASCII
0=2400
1=4800
2=9600
3=19200
4=38400
5=57600
6=76800
7=115200
8=256000
Set:AT+BAUD=[para]
+OK:success
+ERR=[NUM]:error
Description: Restart takes effect, save when power off
5.3 Read and configure stop bits
Command
Respond
Parameter
Request:AT+STOPB?
+OK=[para]
Para:0,1 ASCII
0:1 stop bit
1:2 stop bit
Set:AT+STOPB=[para]
+OK:success
+ERR=[NUM]:error
Description: Restart takes effect, save when power off
5.4 Read/Set serial verification bits
Command
Respond
Parameter
Request:AT+PARI?
+OK=[para]
Para:0,1,2 ASCII
0:No parity;
1:Odd Parity;
2:even parity;
Set:AT+PARI=[para]
+OK:success
+ERR=[NUM]:error
Description: Restart takes effect, save when power off
5.5 Check current broadcasting status, turn on general broadcasting, IBeacon
broadcasting, turn off broadcasting
Command
Respond
Parameter
Request:AT+ADVEN?
+OK=[para]
Para:0、1、2 ASCII
0:Turn off the broadcast
1:General broadcasting
2:iBeacon broadcast
Set:AT+ADVEN=[para]
+OK:success
+ERR=[NUM]:error