Phau Ntawv Qhia

Table Of Contents
Chengdu Ebyte Electronic Technology Co., Ltd. E90-DTU(xxxSLxx-ETH)_V2.0-AT Instruction Set
Copyright ©2012–2022Chengdu Ebyte Electronic Technology Co., Ltd.
20
Send: AT+HTPHEAD\r\n
Received:\r\n+OK=DEL,User-Agent: Mozilla/5.0\r\n
set up:
Send: AT+HTPHEAD=ADD, Host:www.ebyte.com\r\n
Received:\r\n+OK\r\n
3.6 Query/Set MQTT target platform
Command
AT+MQTTCLOUD
Function
Query/Set MQTT target platform
SendQuery
AT+MQTTCLOUD<CR><LF>
Return
Query
<CR><LF>+OK=<Server><CR><LF>
SendSet
AT+MQTTCLOUD=<Server><CR><LF>
ReturnSet
<CR><LF>+OK<CR><LF>
Remarks
Server (MQTT target platform):
STANDARD (MQTT3.1.1 standard protocol server)
ONENET (OneNET-MQTT server)
ALI (Alibaba Cloud MQTT server)
BAIDU (Baidu Cloud MQTT Server)
HUAWEI (Huawei Cloud MQTT Server)
Example
Inquire:
Send: AT+MQTTCLOUD\r\n
Received:\r\n+OK=STANDARD\r\n
set up:
Send: AT+MQTTCLOUD=BAIDU\r\n
Received:\r\n+OK\r\n
3.7 Query/set MQTT keep-alive heartbeat packet sending cycle
Command
AT+MQTKPALIVE
Function
Query/set MQTT keep-alive heartbeat packet sending cycle
SendQuery
AT+MQTKPALIVE<CR><LF>
Return
Query
<CR><LF>+OK=<Time><CR><LF>
SendSet
AT+MQTKPALIVE=<Time><CR><LF>
ReturnSet
<CR><LF>+OK<CR><LF>
Remarks
Time: MQTT keep-alive heartbeat time (limit 1-255 seconds, default
60s, it is not recommended to modify)
Example
Inquire: