Phau Ntawv Qhia

Table Of Contents
Chengdu Ebyte Electronic Technology Co., Ltd. E90-DTU(xxxSLxx-ETH)_V2.0-AT Instruction Set
Copyright ©2012–2022Chengdu Ebyte Electronic Technology Co., Ltd.
11
ReturnSet
<CR><LF>+OK<CR><LF>
Remarks
Status: OFF - Disabled
OLMAC - Send MAC on first connection
OLCSTM - First Connection Send Custom
EMBMAC - send MAC per packet
EMBCSTM - Send Per Packet Custom
Example
Inquire:
Send: AT+REGMOD\r\n
Received:\r\n+OK=OFF\r\n
set up:
Send: AT+UARTCLR=OLMAC\r\n
Received:\r\n+OK\r\n
1.19 Query/set custom registration package content
Command
REGINFO
Function
Query/set custom registration package content
SendQuery
AT+HEARTINFO<CR><LF>
Return
Query
<CR><LF>+OK=<Mode><Data><CR><LF>
SendSet
AT+HEARTINFO=<Mode><Data><CR><LF>
ReturnSet
<CR><LF>+OK<CR><LF>
Remarks
Mode: data format (HEX) hexadecimal, (STR) string;
Data data: ASCII limit is 40 bytes, HEX limit is 20 bytes;
Example
Inquire:
Send: AT+REGINFO\r\n
Received:\r\n+OK=STR,regist msg\r\n
set up:
Send: AT+REGINFO=STR,EBTYE TEST\r\n
Received:\r\n+OK\r\n
1.20 Query/set the heartbeat packet mode
Command
AT+HEARTMOD
Function
Query/set the heartbeat packet mode
SendQuery
AT+ HEARTMOD<CR><LF>
Return
Query
<CR><LF>+OK=<Mode><Time><CR><LF>