Cut Sheet

Eliminate flaring for fast leak free connections
EBRILSMART MAKES INSTALLATION “SMART”
EBRILSMART technical characteristics
DWorking temperature: -45°C to 150°C
DMaximum operating pressure: 45 bar
DSuitable for all refrigerants HCFC, HFC, HC
DTriple metallic seal
DCompatible with traditional 45° flare fittings
DIt is not required the use of a torque wrench
for the installation
DTo be used exclusively on R220 annealed copper tubes
and OH111 aluminium tubes
EBRILSMART certification
DTested according to the requirements in Standard UL 109
DConformity with European Directives (PED, RoHS and REACH
DSuperior performance than the traditional 45° flare fittings
Leakage test EN 1779.B6
Test which calculates the annual loss
of refrigerant, the recommended
threshold is 1 g/year; it was
measured a loss of < 50 mg/year
Burst test EN 378-2
Test in which is evaluated the
pressure resistance of the fittings,
fittings were tested and
remained intact at a maximum
pressure of 200 bar
LABORATORY TESTS
Instructions to perform a proper installation of EBRILSMART
Tutorial on
Insert the tube, previously cut and deburred,
into the nut and the insert the sleeve. Bevel
of sleeve toward nut. Lubricate the inner
surface of the nut.

Summary of content (2 pages)