Datasheet

AC axial compact fan
sickle-shaped blades (S series)
W2E250-HL06-01
Curves: Air performance 60 Hz
Druck p f s[Pa]für Rho=1,2kg/m^3
qv[m^3/h]
2.2002.0001.8001.6001.4001.2001.0008006004002000
qv[cfm]
1.2001.0008006004002000
p f s[Pa]
200
190
180
170
160
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
pfs _E[IN H2O]
0,8
0,75
0,7
0,65
0,6
0,55
0,5
0,45
0,4
0,35
0,3
0,25
0,2
0,15
0,1
0,05
0
p f s[Pa]
1
2
3
4
Measurement: LU-59960-1
Air performance measured according to ISO
5801 installation category A. For detailed
information on the measurement setup,
contact ebm-papst. Intake sound level:
Sound power level according to ISO 13347 /
sound pressure level measured at 1 m
distance from fan axis. The values given are
valid under the specified measuring
conditions and may vary due to conditions of
installation. For deviations from the standard
configuration, the parameters have to be
checked on the installed unit.
Measured values
1
2
3
4
U
V
230
230
230
230
f
Hz
60
60
60
60
n
min
-1
2700
2575
2485
2370
P
e
W
180
186
189
192
I
A
0.79
0.82
0.83
0.84
q
V
m
3
/h
1970
1755
1560
1235
p
fs
Pa
0
40
70
100
q
V
cfm
1160
1030
920
725
p
fs
inH2O
0.00
0.16
0.28
0.40
U = Power supply · f = Frequency · n = Speed (rpm) · P
e
= Power consumption · I = Current draw · q
V
= Air flow · p
fs
= Pressure increase
Item no. 10763-5-9980 · ENU · Change 88948 · Approved 2016-08-25 · Page 5 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com