Datasheet

Product Data Sheet RG225-55/18/2TDMO
02/01/2019 page 7 of 15
Speed control:
By analog voltage 0 - 10 V
Information to the curve analog:
0 V - < 1,3 V: 0 1/min
1,3 V: 800 1/min (Fan on, comming from von 0 V)
1,3 V - 1,6 V: 800 1/min (corresponding to min. speed)
1,6 V - 9,4 V: linear increasing curve
9,4 V - 10 V: 2800 1/min (corresponding to max. speed)
1,3 V - > 1,0 V: linear decreasing curve (comming from 10 V)
1,0 V: 600 1/min or 0 1/min (Fan off, comming from 10 V)
All values are measured in the housing!
Fan doesn't have a sensor break detection!
3.2 Electrical Operating Data
Measurement
conditions:
Normal air density = 1,2 kg/m3; Temperature 23°C +/ - 3°C; Motor axis horizontal; warm-up
time before measuring 5 minutes (unless otherwise specified). In the intake and outlet area
should not be any solid obstruction within 0,5 m.
p = 0:
corresp. to free air flow (see chapter aerodynamics)
I:
corresp. to arithm. mean current value
Name Condition
U Contr. 0001 U Contr.: 10 V
Features Condition Symbol Values
Voltage range U 36 V 72 V
Nominal voltage U
N
48 V
Power consumption 103 W 115 W 126 W
+- 10 % +- 10,0 % +- 10,0 %
Tolerance
p = 0
U Contr. 0010
P
Current consumption 2.850 mA 2.500 mA 1.750 mA
+- 10,0 % +- 10,0 % +- 10,0 %
Tolerance
p = 0
U Contr. 0010
I
Speed 2.650 1/min 2.800 1/min 2.800 1/min
+- 10,0 % +- 5,0 % +- 5,0 %
Tolerance
p = 0
U Contr. 0010
n