Datasheet
Product Data Sheet RG190-39/14/2TDMO-221
02/02/2019 page 9 of 13
Max. residual current at U
N
I
F
<= 5 mA
Locked rotor protection Auto restart
Locked rotor current at U
N
I
block
approx. 2.400 mA
Clock signal at locked rotor
t
3
/ t
4
typical: 2,6 s / 10,0 s
Locked rotor signal t5:
After 4 failed start-ups there is an extended timeout of 40,0s.
3.5 Data According ErP Directive
Installation / Efficency category A / static
Speed control integrated
Specific ratio 1,00473
Target overall efficiency 2015 41,4 %
Overall efficiency 51,7 %
Efficiency grade 61
Power input 135,6 W
Speed 3.900 1/min
All values measured in optimum energy efficiency point.
Productiondatecode is printed on the fan label.