Datasheet
Product Data Sheet RG160-28/14NTDT
01/31/2019 page 6 of 9
3.3 Electrical Features
Electronic function Speed-Controlled
Reversed polarity protection P-CH FET
Max. residual current at U
N
I
F
<= 20 mA
Locked rotor protection Auto restart
Locked rotor current at U
N
I
block
approx. 760 mA
Clock signal at locked rotor
t
3
/ t
4
typical: 1,0 s / 3,1 s
3.4 Aerodynamics
Measurement
conditions:
Measured with a double chamber intake rig acc. to DIN EN ISO 5801.
Normal air density = 1,2 kg/m3; Temperature 23°C +/ - 3°C;
In the intake and outlet area should not be any solid obstruction within 0,5 m. Motor shaft
horizontal.
The information is only valid under the specified test conditions and may be changed by the
installation conditions. If there are deviations from the standard test conditions, the
characteristic values must be checked under the installed conditions.
a.) Operation condition:
4.200 1/min at free air flow TU >= 50 °C
Max. free-air flow (∆p = 0 /
= max.) 308,0 m3/h
Max. static pressure (∆p = max. /
=0) 780 Pa