Product Data Sheet RG160-28/14NTDT Product Data Sheet RG160-28/14NTDT The engineer's choice
Product Data Sheet RG160-28/14NTDT RG160-28/14NTDT INDEX 1 General ............................................................................................................................................................... 3 2 Mechanics .......................................................................................................................................................... 3 2.1 2.2 3 Operating Data ..................................................................................
Product Data Sheet RG160-28/14NTDT 1 General Fan type Rotating direction looking at rotor Airflow direction Bearing system Mounting position - shaft 2 Mechanics 2.1 General Blower Counterclockwise Air in axially, Air out radially Ball bearing Any Width Height Depth Mass Housing material Impeller material Max. torque when mounted across both mounting flanges; Metal flange on mounting plate Screw size 2.
Product Data Sheet RG160-28/14NTDT 3 Operating Data 3.
Product Data Sheet RG160-28/14NTDT 3.2 Electrical Operating Data Measurement conditions: ∆p = 0: I: Normal air density = 1,2 kg/m3; Temperature 23°C +/ - 3°C; Motor axis horizontal; warm-up time before measuring 5 minutes (unless otherwise specified). In the intake and outlet area should not be any solid obstruction within 0,5 m. corresp. to free air flow (see chapter aerodynamics) corresp. to arithm.
Product Data Sheet RG160-28/14NTDT 3.3 Electrical Features Electronic function Reversed polarity protection Max. residual current at UN Locked rotor protection Locked rotor current at UN Clock signal at locked rotor 3.4 Speed-Controlled P-CH FET IF <= 20 mA Auto restart Iblock approx. 760 mA t3 / t4 typical: 1,0 s / 3,1 s Aerodynamics Measurement conditions: Measured with a double chamber intake rig acc. to DIN EN ISO 5801.
Product Data Sheet RG160-28/14NTDT 3.5 Sound Data Measurement conditions: Sound pressure level: 1 meter distance between microphone and the air intake. Sound power level: Acc. to DIN 45635 part 38 (ISO 10302) Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 dB(A) For further measurement conditions see chapter aerodynamics. a.) Operation condition: 4.
Product Data Sheet RG160-28/14NTDT 5 Safety 5.1 Electrical Safety Dielectric strength DIN EN 60950 (VDE 0805) and DIN EN 60335 (VDE 0700) A.) Type test Measuring conditions: After 48h of storage at 95% R.H. and 25°C. No arcing or breakdown is allowed! All connections together to ground. B.) Routine test Measuring conditions: At indoor climate. No arcing or breakdown is allowed! All connections together to ground. Isolation resistance Measuring conditions: After 48h of storage at 95% R.H.