Datasheet

Product Data Sheet RG160-28/14NTDH
02/02/2019 page 4 of 10
3 Operating Data
3.1 Electrical Operating Data
Measurement
conditions:
Normal air density = 1,2 kg/m3; Temperature 23°C +/ - 3°C; Motor axis horizontal; warm-up
time before measuring 5 minutes (unless otherwise specified). In the intake and outlet area
should not be any solid obstruction within 0,5 m.
p = 0:
corresp. to free air flow (see chapter aerodynamics)
I:
corresp. to arithm. mean current value
Features Condition Symbol Values
Voltage range U 16 V 28 V
Nominal voltage U
N
24 V
Power consumption 48 W 101 W 96 W
+- 15 % +- 15,0 % +- 15,0 %
Tolerance
p = 0
0010
P
Current consumption 3.000 mA 4.200 mA 3.200 mA
+- 15,0 % +- 15,0 % +- 15,0 %
Tolerance
p = 0
0010
I
Speed 4.000 1/min 5.000 1/min 5.000 1/min
+- 7,5 % +- 7,5 % +- 7,5 %
Tolerance
p = 0
0010
n
Motor testing
The motor testing relates to a fan, operating with horizontal shaft, at free wir flow. It is possible to run this motor in an
uncontrolled state. For some testings the motor may set in a test cycle by connecting to a voltage follower as below
mentioned.
Voltage graph to start the test cycle