3.2 Electrical Interface - Output
Tacho type /12 (TTL)
Features Note Values
Tacho operating voltage U
BS
5 V
Tacho signal TTL High Min.: 2,5 V Max.: 5,5 V
Tacho signal Low U
S low
I sink: 2 mA <= 0,4 V
Tacho signal High U
S high
I source: 1 mA
Maximum sink current I
sink
<= 5 mA
Maximum source current 1 mA
External resistor All voltages measured to GND.
Tacho frequency (2 x n) / 60
Tacho isolated from motor No
Slew rate => 0,5 V/us
n = revolutions per minute (1/min)
3.3 Electrical Features
Electronic function None
Reversed polarity protection Rectifying diode
Max. residual current at U
N
I
F
<= 12 mA
Locked rotor protection Auto restart
Locked rotor current at U
N
I
block
approx. 3.500 mA
Clock signal at locked rotor
t
3
/ t
4
typical: 2,6 s / 6,9 s