Datasheet

Product Data Sheet RG160-28/12/2NP-211
02/02/2019 page 11 of 12
5 Safety
5.1 Electrical Safety
Dielectric strength
DIN EN 60950 (VDE 0805) and DIN EN 60335 (VDE 0700)
A.) Type test
Measuring conditions: After 48h of storage at 95% R.H. and
25°C.
No arcing or breakdown is allowed!
All connections together to ground.
500 VAC / 1 Min.
B.) Routine test
Measuring conditions: At indoor climate.
No arcing or breakdown is allowed!
All connections together to ground.
850 VDC / 1 Sec.
Isolation resistance
Measuring conditions: After 48h of storage at 95% R.H. and
25°C measured with U=500 VDC for 1 min.
RI > 10 MOhm
Clearance / creepage distance 1,0 mm / 1,2 mm
Protection class III
5.2 Approval Tests
CE
EC Declaration of Conformity
No
EAC
Eurasian Conformity
Yes
UL
Underwriters Laboratories
No
VDE
Association for Electrical, Electronic and Information
Technologies
No
CSA
Canadian Standards Association
No
CCC
China Compulsory Certification
Not applicable
6 Reliability
6.1 General
Life expectancy L10 at TU = 40 °C 75.000 h
Life expectancy L10 at TU max. 35.000 h
Life expectancy L10 acc. to IPC 9591 at TU = 40 °C 127. 500 h