Datasheet

Product Data Sheet RG125-19/14NR
01/31/2019 page 4 of 9
3 Operating Data
3.1 Electrical Operating Data
Measurement
conditions:
Normal air density = 1,2 kg/m3; Temperature 23°C +/ - 3°C; Motor axis horizontal; warm-up
time before measuring 5 minutes (unless otherwise specified). In the intake and outlet area
should not be any solid obstruction within 0,5 m.
p = 0:
corresp. to free air flow (see chapter aerodynamics)
I:
corresp. to arithm. mean current value
Features Condition Symbol Values
Voltage range U 12 V 28,0 V
Nominal voltage U
N
24,0 V
Power consumption 1,1 W 4,9 W 6,7 W
+- 17,5 % +- 12,5 % +- 15,0 %
Tolerance
p = 0
0010
P
Current consumption 94 mA 203 mA 240 mA
+- 17,5 % +- 12,5 % +- 15,0 %
Tolerance
p = 0
0010
I
Speed 1.365 1/min 2.550 1/min 2.840 1/min
+- 12,5 % +- 7,5 % +- 10,0 %
Tolerance
p = 0
0010
n
Starting current
consumption
< 900 mA
3.2 Electrical Features
Electronic function None
Reversed polarity protection Rectifying diode
Max. residual current at U
N
I
F
<= 10 mA
Locked rotor protection Auto restart
Locked rotor current at U
N
I
block
approx. 900 mA
Clock signal at locked rotor
t
3
/ t
4
typical: 0,6 s / 10 s