Datasheet

Product Data Sheet RET97-25/18/2TDP
01/31/2019 page 13 of 15
Duration
Number of bumps (+X, -X, -Y, +Y, -Z, +Z)
Total bumps
6 ms
100 in each direction
600
mobile use Random vibration in use
IEC 60068-2-64
Frequency range / ASD
G
RMS
Axes of vibration
Test duration
Random vibration
5 - 20 Hz : 2,0 m
2
/ s
3
20- 150 Hz : - 3 dB / Oct
0,83 G
3
3 x 5 h
mobile use Shock in use
IEC 60068-2-27
Shock spectrum
Acceleration
Duration
Number of bumps (+X, -X, -Y, +Y, -Z, +Z)
Total bumps
Shock
half sine
30 G
6 ms
10 in each direction
60
mobile use Bump in use
IEC 60068-2-29
Shock spectrum
Acceleration
Duration
Number of bumps (+X, -X, -Y, +Y, -Z, +Z)
Total bumps
Bump
half sine
5 G
11 ms
100 in each direction
600
severity level Railroad application
1
IEC 61373
Category 1
Class B
Random vibration in use
IEC 60068-2-64
Frequency range / ASD
G
RMS
Axes of vibration
Test duration
Random vibration
5 - 20 Hz : 2,0 m
2
/ s
3
20- 150 Hz : - 3 dB / Oct
0,83 G
3
3 x 5 h
Shock in use
IEC 60068-2-27
Shock spectrum
Acceleration
Duration
Number of bumps (+X, -X, -Y, +Y, -Z, +Z)
Total bumps
Shock
half sine
7 G
18 ms
10 in each direction
60