Datasheet
Product Data Sheet RER225-63/18/2TDO-402
02/01/2019 page 8 of 13
Locked rotor protection Auto restart
Locked rotor current at U
N
I
block
approx. 3.000 mA
Clock signal at locked rotor
t
3
/ t
4
typical: 3 s / 10,0 s
Locked rotor signal t5:
After 2 failed start-ups there is an extended timeout of 50 s.
3.5 Data According ErP Directive
Installation / Efficency category A / static
Speed control integrated
Specific ratio 1,00502
Target overall efficiency 2015 45,0 %
Overall efficiency 55,4 %
Efficiency grade 62
Power input 240,9 W
Speed 3.260 1/min
All values measured in optimum energy efficiency point.
Productiondatecode is printed on the fan label.