Datasheet

Product Data Sheet RER220-43/18/2TDO
02/02/2019 page 13 of 15
Ceck accuracy / Limit 10 V/m; 80 - 1000 MHz; AM; m = 0,8; f = 1 kHz; 1%; t = 3 s
Result A: The monitored function operates as designed during and after exposure
to a disturbance.
Kind Electrical Fast Transient / Burst Immunity Test
According DIN EN 61000-4-4:2005-07
Ceck accuracy / Limit +/- 2 kV on Power Lines; Coupling: POS, NEG, {PE}, ALL, 5 kHz and 100
kHz; 1 min
Result A: The monitored function operates as designed during and after exposure
to a disturbance.
Kind Immunity to Conducted Disturbances, Induced by RF-Fields
According DIN EN 61000-4-6:2001-12
Ceck accuracy / Limit 10 Vrms; 150 kHz - 80 MHz; m = 0,8; f = 1 kHz; 1%; t = 3 s
Result A: The monitored function operates as designed during and after exposure
to a disturbance.