Datasheet
Product Data Sheet RER190-39/18/2TDMOU-232
01/31/2019 page 9 of 15
Locked rotor protection Auto restart
Locked rotor current at U
N
I
block
approx. 1.700 mA
Clock signal at locked rotor
t
3
/ t
4
typical: 6,5 s / 10,0 s
Locked rotor signal t5:
After 4 failed start-ups there is an extended timeout of 40,0s.
3.5 Data According ErP Directive
Installation / Efficency category A / static
Speed control integrated
Specific ratio 1,00548
Target overall efficiency 2015 43,2 %
Overall efficiency 55,0 %
Efficiency grade 62
Power input 162 W
Speed 4.160 1/min
All values measured in optimum energy efficiency point.
Productiondatecode is printed on the fan label.