Datasheet

Product Data Sheet RER190-39/14/2TDMO
02/01/2019 page 9 of 14
Locked rotor protection Auto restart
Locked rotor current at U
N
I
block
approx. 3.950 mA
Clock signal at locked rotor
t
3
/ t
4
typical: 3,6 s / 10,0 s
Locked rotor signal t5:
After 4 failed start-ups there is an extended timeout of 40 s.
3.5 Data According ErP Directive
Installation / Efficency category A / static
Speed control integrated
Specific ratio 1,00482
Target overall efficiency 2015 42,4 %
Overall efficiency 56,2 %
Efficiency grade 62
Power input 135,7 W
Speed 3.900 1/min
All values measured in optimum energy efficiency point.
Productiondatecode is printed on the fan label.