Datasheet
Product Data Sheet RER175-42/14/2TDMP
01/31/2019 page 8 of 13
Max. residual current at U
N
I
F
<= 5 mA
Locked rotor protection Auto restart
Locked rotor current at U
N
I
block
approx. 2.300 mA
Clock signal at locked rotor
t
3
/ t
4
typical: 2,3 s / 10,0 s
Locked rotor signal t5:
After 4 failed start-ups there is an extended timeout of 40 s.
3.5 Data According ErP Directive
Installation / Efficency category A / static
Speed control integrated
Specific ratio 1,00455
Target overall efficiency 2015 43,0 %
Overall efficiency 46,9 %
Efficiency grade 62
Power input 154,2 W
Speed 4.630 1/min
All values measured in optimum energy efficiency point.
Productiondatecode is printed on the fan label.