3.6 Sound Data
Measurement
conditions:
Sound pressure level: 1 meter distance between microphone and the air intake.
Sound power level: Acc. to DIN 45635 part 38 (ISO 10302)
Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 dB(A)
For further measurement conditions see chapter aerodynamics.
a.) Operation condition:
4.000 1/min at free air flow U Contr. 10,0 V
Optimal operating point 220,0 m3/h @ 222 Pa
Sound power level at the optimal operating
point
6,9 bel(A)
Sound pressure level at free air flow,
measured in rubber bands
4 Environment
4.1 General
Min. permitted ambient temperature TU min. -20 °C
Max. permitted ambient temperature TU max. 70 °C
Min. permitted storage temperature TL min. -40 °C
Max. permitted storage temperature TL max. 80 °C
4.2 Climatic Requirements
IP-protection type (certified) IP 68 (for fan only, not for connector if applicable) **)
Humidity requirements humid temperature, cyclic; according to DIN EN 60068-2-38, 10
cycle and condensation water check; according to DIN EN ISO
6270-2, 14 days
Salt fog requirements salt fog, cyclic, in operation; according to DIN EN 60068-2-52, 3
cycle
Permitted application area:
The product is for the use in open and unsheltered areas. Direct exposure to water as well as saline ambient
conditions are allowed provided that this does not prevent the normal operation.
Pollution degree 3 (according DIN EN 60664-1)
It occurs conductive pollution or dry non-conductive pollution which becomes conductive due to condensation.
**) The specification of the IP protection refers to the conditions mentioned in certification of the fan. The above
mentioned short description of the protection scope is not final. For detailed information of the respective protection
scope and definitions, see certification as well as DIN EN 60529 (protection by housings) and ISO 20653 (for vehicles)
with the letter K.
Short description of the IP-protection type:
Solid particle Protection: Dust tight.
Protection against deliberate contact: Protected against contact to hazardous parts with a wire.
Protection against water: The fan test according to IP68 (Based on IEC 60529), is conducted in non-operating mode.
The fan is tested by a complete immersion in water for a period of 2h at a water-level of 1,2m. Electrical connections
are not immersed since they are customer specific.