Product Data Sheet RER133-41/14/2TDP Product Data Sheet RER133-41/14/2TDP The engineer's choice
Product Data Sheet RER133-41/14/2TDP RER133-41/14/2TDP INDEX 1 General ............................................................................................................................................................... 3 2 Mechanics .......................................................................................................................................................... 3 2.1 2.2 3 Operating Data ..............................................................................
Product Data Sheet RER133-41/14/2TDP 1 General Fan type Rotating direction looking at rotor Airflow direction Bearing system Mounting position - shaft 2 Mechanics 2.1 General Depth Diameter Mass Housing material Impeller material 2.
Product Data Sheet RER133-41/14/2TDP Lead wire 1 - 2: AWG20 Lead wire 3 - 4: AWG22 (Insulation diameter 2,05mm) (Insulation diameter 1,35mm) 02/02/2019 page 4 of 13
Product Data Sheet RER133-41/14/2TDP 3 Operating Data 3.1 Electrical Interface - Input Control input PWM Features Inpute type PWM - Frequency Open collector 1 kHz - 10 kHz typical: 2 kHz Characteristics Schematics Speed control: By Puls-width-modulation (PWM) 0 ...
Product Data Sheet RER133-41/14/2TDP Information to the curve: 0 % - 7% PWM: 0 1/min 7 % PWM: 800 1/min (Fan on, comming from 0% PWM) 7 % - 10% PWM: 800 1/min (corresponding to min. speed) 10 % - 90% PWM: linear increasing curve 90 % - 100% PWM: 6.000 1/min (corresponding to max. speed) 7 % - 5 % PWM: linear decreasing curve (comming from 100% PWM) 5 % PWM: 600 1/min or 0 1/min (Fan off, comming from 100% PWM) 3.
Product Data Sheet RER133-41/14/2TDP 3.3 Electrical Interface - Output Tacho type Features Tacho operating voltage Tacho signal Low Tacho signal High Maximum sink current Maximum source current External resistor Tacho frequency Tacho isolated from motor Slew rate /2 (open collector) Note UBS US low US high Isink Values <= 60 V I sink: 2 mA <=0,4 V I source: 0 mA <=60,0 V <= 20 mA 0 mA External resistor Ra from UBS to US required. All voltages measured to GND.
Product Data Sheet RER133-41/14/2TDP Max. residual current at UN Locked rotor protection Locked rotor current at UN Clock signal at locked rotor IF <= 5 mA Auto restart Iblock approx. 1.300 mA t3 / t4 typical: 5,5 s / 10,0 s Locked rotor signal t5: After 4 failed start-ups there is an extended timeout of 40 s.
Product Data Sheet RER133-41/14/2TDP 3.5 Aerodynamics Measurement conditions: Measured with a double chamber intake rig acc. to DIN EN ISO 5801. Normal air density = 1,2 kg/m3; Temperature 23°C +/ - 3°C; In the intake and outlet area should not be any solid obstruction within 0,5 m. Motor shaft horizontal. The information is only valid under the specified test conditions and may be changed by the installation conditions.
Product Data Sheet RER133-41/14/2TDP 02/02/2019 page 10 of 13
Product Data Sheet RER133-41/14/2TDP 3.6 Sound Data Measurement conditions: Sound pressure level: 1 meter distance between microphone and the air intake. Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 dB(A) For further measurement conditions see chapter aerodynamics. a.) Operation condition: 6.000 1/min at free air flow 4 Environment 4.1 General PWM 100 %; f: 2 kHz Min. permitted ambient temperature TU min. Max. permitted ambient temperature TU max. Min.
Product Data Sheet RER133-41/14/2TDP 5 Safety 5.1 Electrical Safety Dielectric strength DIN EN 60950 (VDE 0805) and DIN EN 60335 (VDE 0700) A.) Type test Measuring conditions: After 48h of storage at 95% R.H. and 25°C. No arcing or breakdown is allowed! All connections together to ground. B.) Routine test Measuring conditions: At indoor climate. No arcing or breakdown is allowed! All connections together to ground. Isolation resistance Measuring conditions: After 48h of storage at 95% R.H.