Datasheet

Product Data Sheet RER133-41/14/2TDMP
02/01/2019 page 5 of 12
Please note:
It's possible to control the fan by a control voltage of
0... 5 V. (5 V corresponds to 100 % PWM).
The power supply must be able to "sink" and works together with an internal pull-up resistor (4,7 kOhm).
Information to the curve:
0 % - 7% PWM: 0 1/min
7 % PWM: 800 1/min (Fan on, comming from 0% PWM)
7 % - 10% PWM: 800 1/min (corresponding to min. speed)
10 % - 90% PWM: linear increasing curve
90 % - 100% PWM: 5.000 1/min (corresponding to max. speed)
7 % - 5 % PWM: linear decreasing curve (comming from 100% PWM)
5 % PWM: 600 1/min or 0 1/min (Fan off, comming from 100% PWM)
3.2 Electrical Operating Data
Measurement
conditions:
Normal air density = 1,2 kg/m3; Temperature 23°C +/ - 3°C; Motor axis horizontal; warm-up
time before measuring 5 minutes (unless otherwise specified).
In the intake and outlet area should not be any solid obstruction within 0,5 m.
Measurement setup: Measured between two steel plates
Steel plate: 140 mm x 140 mm
Intake nozzle: D: 87 mm; R: 7 mm
Distance between bottom and top plate: 101 mm
Overlapping impeller / nozzle: 2 mm
p = 0: corresp. to free air flow (see chapter aerodynamics)
I: corresp. to arithm. mean current value
Name Condition
PWM 0001 PWM: 95 %; f: 2 kHz
100% PWM; f = 2 kHz or broken lead wire (open control input)
The data at 50% PWM are no FK features and need not be tested.
Features Condition Symbol Values
Voltage range U 16 V 30 V
Nominal voltage U
N
24,0 V
Power consumption 38,4 W 58,0 W 60,5 W
+- 10 % +- 10 % +- 10 %
Tolerance
p = 0
PWM 0010
P
Current consumption 2.400 mA 2.400 mA 2.000 mA
+- 10 % +- 10 % +- 10 %
Tolerance
p = 0
PWM0010
I
Speed 4.330 1/min 5.000 1/min 5.000 1/min
+- 7,5 % +- 5 % +- 5 %
Tolerance
p = 0
PWM 0010
n