Datasheet

Product Data Sheet RER120-26/18/2TDMP-005
02/01/2019 page 7 of 12
Max. residual current at U
N
I
F
<= 5 mA
Locked rotor protection Auto restart
Locked rotor current at U
N
I
block
approx. 1.000 mA
Clock signal at locked rotor
t
3
/ t
4
typical: 4,6 s / 10,0 s
Locked rotor signal t5:
After 4 failed start-ups there is an extended timeout of 40 s.
Internal Fuse:
Littelfuse NANO2(R) FUSE; Very fast acting 451 Series; 2,5 A