Datasheet
Product Data Sheet RER101-36/12N/2HHPR
01/31/2019 page 5 of 12
3.2 Electrical Operating Data
Measurement
conditions:
Normal air density = 1,2 kg/m3; Temperature 23°C +/ - 3°C; Motor axis horizontal; warm-up
time before measuring 5 minutes (unless otherwise specified).
In the intake and outlet area should not be any solid obstruction within 0,5 m.
Measurement setup: Measured between two steel plates
Steel plate: 148 mm x 148 mm
Intake nozzle: D: 66 mm; R: 7 mm
Distance between bottom and top plate:
Overlapping impeller / nozzle: 1 mm
∆p = 0: corresp. to free air flow (see chapter aerodynamics)
I: corresp. to arithm. mean current value
Name Condition
PWM 0001 PWM: 0 %; f: 10 kHz f: 20 kHz
Features Condition Symbol Values
Voltage range U 9 V 13,6 V
Nominal voltage U
N
12,0 V
Power consumption 9,9 W 21 W 28,3 W
+- 10,0 % +- 10,0 % +- 10,0 %
Tolerance
∆p = 0
PWM 0010
P
Current consumption 1.100 mA 1.700 mA 2.050 mA
+- 10,0 % +- 10,0 % +- 10,0 %
Tolerance
∆p = 0
PWM0010
I
Speed 4.550 1/min 6.000 1/min 6.600 1/min
+- 10,0 % +- 10,0 % +- 10,0 %
Tolerance
∆p = 0
PWM 0010
n