Datasheet
Product Data Sheet REF175-30/18/2TDP
01/31/2019 page 6 of 13
Information to the curve:
0 % - 7% PWM: 0 1/min
7 % - 10% PWM: 800 1/min (corresponding to min. speed)
10 % - 90% PWM: linear increasing curve
90 % - 100% PWM: 5.400 1/min (corresponding to max. speed)
7 % PWM: 800 1/min (Fan on, comming from 0% PWM)
5 % PWM: 600 1/min or 0 1/min (Fan off, comming from 100% PWM)
3.2 Electrical Operating Data
Measurement
conditions:
Normal air density = 1,2 kg/m3; Temperature 23°C +/ - 3°C; Motor axis horizontal; warm-up
time before measuring 5 minutes (unless otherwise specified).
In the intake and outlet area should not be any solid obstruction within 0,5 m.
Measurement setup: Measured between two steel plates
Steel plate: 180 mm x 180 mm
Intake nozzle: D: 125,5 mm; R: 10 mm
Distance between bottom and top plate: 64,5 mm
Overlapping impeller / nozzle: 2 mm
∆p = 0: corresp. to free air flow (see chapter aerodynamics)
I: corresp. to arithm. mean current value
Name Condition
PWM 0001 PWM: 100 %; f: 2 kHz
The data at 50% are no FK features and need not be tested.
Electrical operating data with intake nozzle (for test purposes) according to 10pcs protocol at plant
Herbolzheim.
Features Condition Symbol Values
Voltage range U 36 V 72 V
Nominal voltage U
N
48 V
Power consumption 94 W 154 W 158 W
+- 15 % +- 10 % +- 10 %
Tolerance
∆p = 0
PWM 0010
P
Current consumption 2.600 mA 3.200 mA 2.200 mA
+- 15 % +- 10 % +- 10 %
Tolerance
∆p = 0
PWM0010
I
Speed 3.800 1/min 4.400 1/min 4.400 1/min
+- 7,5 % +- 7,5 % +- 7,5 %
Tolerance
∆p = 0
PWM 0010
n