Datasheet

Product Data Sheet REF100-11/12/2
01/31/2019 page 9 of 11
Kind Radiated Emission; 30 MHz - 1000 MHz
According DIN EN 55032:2016-02
Ceck accuracy / Limit Class B
Result Below limit Class B
Kind Electrostatic Discharge Immunity Test
According DIN EN 61000-4-2:2001-12
Ceck accuracy / Limit Contact Discharge +/- 4 kV; Air Discharge +/- 8 kV
Result B: The monitored function may deviate from designed performance to a
specified level during exposure to a disturbance or revert to a fail safe
mode or operation, but shall return to normal operation after the
disturbance is removed.
Kind Electromagnetic Field Immunity Test
According DIN EN 61000-4-3:2006-12
Ceck accuracy / Limit 10 V/m; 80 - 1000 MHz; AM; m = 0,8; f = 1 kHz; 1%; t = 3 s
Result A: The monitored function operates as designed during and after exposure
to a disturbance.
Kind Electrical Fast Transient / Burst Immunity Test
According DIN EN 61000-4-4:2005-07
Ceck accuracy / Limit +/- 2 kV on Power Lines; Coupling: POS, NEG, {PE}, ALL, 5 kHz and 100
kHz; 1 min
Result B: The monitored function may deviate from designed performance to a
specified level during exposure to a disturbance or revert to a fail safe
mode or operation, but shall return to normal operation after the
disturbance is removed.