Datasheet
EC centrifugal fan
forward curved, single inlet
with housing (flange)
G3G120-BB01-06
Charts: Air flow 50 Hz
qv m³/h
cfm
Pfs
Pa
in wg
50 100 150 200
0 40 80 120
50
100
150
200
250
300
0.3
0.6
0.9 1.2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
ρ = 1.15 kg/m³ ± 2 %
Measurement: LU-172500-1
Air performance measured as per ISO 5801
Installation category A. For detailed
information on the measuring set-up, please
contact ebm-papst. Suction-side noise
levels: LwA measured as per ISO 13347 /
LpA measured with 1m distance to fan axis.
The values given are valid under the
measuring conditions mentioned above and
may vary according to the actual installation
situation. With any deviation from the
standard set-up, the specific values have to
be checked and reviewed with the unit
installed.
Measured values
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
U
V
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
f
Hz
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
n
min
-1
2130
2240
2380
2520
2100
2100
2100
2100
1700
1700
1700
1700
1300
1300
1300
1300
P
ed
W
38
33
28
22
37
27
19
13
19
15
10.0
7.0
9.0
7.0
5.0
3.00
I
A
0.30
0.26
0.22
0.18
0.28
0.21
0.15
0.10
0.15
0.11
0.08
0.06
0.07
0.05
0.04
0.02
q
V
m
3
/h
255
215
170
120
250
205
150
100
205
165
120
80
155
125
90
60
p
fs
Pa
0
80
160
230
0
70
124
161
0
46
82
106
0
27
48
62
q
V
cfm
150
125
100
70
145
120
85
60
120
95
70
45
90
75
55
35
p
fs
in. wg
0.00
0.32
0.64
0.92
0.00
0.28
0.50
0.65
0.00
0.18
0.33
0.43
0.00
0.11
0.19
0.25
U = Supply voltage · f = Frequency · n = Speed (rpm) · P
ed
= Power input · I = Current draw · q
V
= Air flow · p
fs
= Pressure increase
Item no. 55004-5-9980 · ENG · Revision 85329 · Release 2017-03-16 · Page 5 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com