Datasheet
AC centrifugal fan
forward-curved, single-intake
with housing (flange)
G2E120-AR77-90
Curves: Air performance 60 Hz
Druck p f s[Pa]für Rho=1,2kg/m^3
qv[m^3/h]
300280260240220200180160140120100806040200
qv[cfm]
180160140120100806040200
p f s[Pa]
460
440
420
400
380
360
340
320
300
280
260
240
220
200
180
160
140
120
100
80
60
40
20
0
pfs _E[IN H2O]
1,85
1,8
1,75
1,7
1,65
1,6
1,55
1,5
1,45
1,4
1,35
1,3
1,25
1,2
1,15
1,1
1,05
1
0,95
0,9
0,85
0,8
0,75
0,7
0,65
0,6
0,55
0,5
0,45
0,4
0,35
0,3
0,25
0,2
0,15
0,1
0,05
p f s[Pa]
1
2
3
4
Measurement: LU-104581-1
Air performance measured according to ISO
5801 installation category A. For detailed
information on the measurement setup,
contact ebm-papst. Intake sound level:
Sound power level according to ISO 13347 /
sound pressure level measured at 1 m
distance from fan axis. The values given are
valid under the specified measuring
conditions and may vary due to conditions of
installation. For deviations from the standard
configuration, the parameters have to be
checked on the installed unit.
Measured values
1
2
3
4
U
V
230
230
230
230
f
Hz
60
60
60
60
n
min
-1
2450
2770
2950
3180
P
e
W
100
92
86
77
I
A
0.44
0.40
0.37
0.34
q
V
m
3
/h
270
225
175
100
p
fs
Pa
0
150
300
380
q
V
cfm
160
130
105
60
p
fs
inH2O
0.00
0.60
1.20
1.53
U = Power supply · f = Frequency · n = Speed (rpm) · P
e
= Power consumption · I = Current draw · q
V
= Air flow · p
fs
= Pressure increase
Item no. 11913-5-9980 · ENU · Change 88948 · Approved 2016-08-25 · Page 5 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com