Datasheet
AC centrifugal fan
forward-curved, single-intake
with housing (flange)
G2E120-AR77-90
Curves: Air performance 50 Hz
Druck p f s[Pa]für Rho=1,2kg/m^3
qv[m^3/h]
280260240220200180160140120100806040200
qv[cfm]
160140120100806040200
p f s[Pa]
350
340
330
320
310
300
290
280
270
260
250
240
230
220
210
200
190
180
170
160
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
pfs _E[IN H2O]
1,4
1,35
1,3
1,25
1,2
1,15
1,1
1,05
1
0,95
0,9
0,85
0,8
0,75
0,7
0,65
0,6
0,55
0,5
0,45
0,4
0,35
0,3
0,25
0,2
0,15
0,1
0,05
0
p f s[Pa]
1
2
3
4
Measurement: LU-104578-1
Air performance measured according to ISO
5801 installation category A. For detailed
information on the measurement setup,
contact ebm-papst. Intake sound level:
Sound power level according to ISO 13347 /
sound pressure level measured at 1 m
distance from fan axis. The values given are
valid under the specified measuring
conditions and may vary due to conditions of
installation. For deviations from the standard
configuration, the parameters have to be
checked on the installed unit.
Measured values
1
2
3
4
U
V
230
230
230
230
f
Hz
50
50
50
50
n
min
-1
2350
2510
2640
2740
P
e
W
80
73
69
66
I
A
0.35
0.33
0.32
0.31
q
V
m
3
/h
260
205
150
95
p
fs
Pa
0
120
240
280
q
V
cfm
150
120
90
55
p
fs
inH2O
0.00
0.48
0.96
1.12
U = Power supply · f = Frequency · n = Speed (rpm) · P
e
= Power consumption · I = Current draw · q
V
= Air flow · p
fs
= Pressure increase
Item no. 11913-5-9980 · ENU · Change 88948 · Approved 2016-08-25 · Page 4 / 5