Datasheet
Product Data Sheet DV4118 N
02/02/2019 page 4 of 10
3 Operating Data
3.1 Electrical Operating Data
Measurement
conditions:
Normal air density = 1,2 kg/m3; Temperature 23°C +/ - 3°C; Motor axis horizontal; warm-up
time before measuring 5 minutes (unless otherwise specified). In the intake and outlet area
should not be any solid obstruction within 0,5 m.
∆p = 0:
corresp. to free air flow (see chapter aerodynamics)
I:
corresp. to arithm. mean current value
Note:
No inrush current at Unom means:
The internal electrolytic capacitor 39uF/100V has no resistor or inrush current limitation, essentially the power supply
and the type and length of the connecting cable is limiting the Inrush current.
Features Condition Symbol Values
Voltage range U 36 V 60,0 V
Nominal voltage U
N
48,0 V
Power consumption 12 W 20,0 W 22,2 W
+- 15 % +- 15,0 % +- 15,0 %
Tolerance
∆p = 0
0010
P
Current consumption 335 mA 420 mA 370 mA
+- 15,0 % +- 15,0 % +- 15,0 %
Tolerance
∆p = 0
0010
I
Speed 4.850 1/min 6.000 1/min 6.000 1/min
+- 10,0 % +- 10,0 % +- 10,0 %
Tolerance
∆p = 0
0010
n
Starting current
consumption
1.600 mA
3.2 Electrical Features
Electronic function Speed-Controlled
Reversed polarity protection Rectifying diode
Max. residual current at U
N
I
F
<= 10 mA
Locked rotor protection Auto restart
Locked rotor current at U
N
I
block
approx. 1.600 mA
Clock signal at locked rotor
t
3
/ t
4
typical: 1,2 s / 5,0 s