Datasheet
Product Data Sheet ACI4400/2HHP
2/28/2019 page 6 of 14
3.2 Electrical Operating Data
Measurement
conditions:
Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C; Motor axis horizontal;warm-up
time before measuring 5 minutes (unless otherwise specified).In the intake and outlet area
should not be any solid obstruction within 0,5 m.
∆p = 0: corresp. to free air flow (see chapter aerodynamics)
I: corresp. to arithm. mean current value
Name Condition
PWM 0001 PWM: > 90 %; f: 1 kHz
Features Condition Symbol
Values
Voltage range
Tolerance
U
100 V
-10,0 %
240 V
10,0 %
Nominal voltage U
N
115 V 230 V
Frequency f 50 Hz / 60 Hz
Power consumption
Tolerance
∆p = 0 P
4,6 W
+- 15 %
Current
consumption
70 mA 63 mA 34 mA 40 mA
Tolerance
∆p = 0 I
RMS
+- 15 % +- 15 % +- 15 % +- 15 %
Speed 3.300 1/min
+- 10 %
Tolerance
∆p = 0 n
**) Vario Pro:
Unless otherwise specified in the table a general fan speed tolerance applies, relating to the
maximum value of the required characteristic curve. Tolerance: +- +- 10 %