Datasheet

Product Data Sheet AC 8300 H
7/10/2017 page 9 of 11
4.2 Climatic Requirements
IP-protection type (certified) IP 20 **)
Humidity requirements humid heat, constant; according to DIN EN 60068-2-
78, 14 days
Salt fog requirements None
Permitted application area:
The product is intended for use in sheltered rooms with controlled temperature and controlled humidity. Directly
exposure to water must be avoided.
Pollution degree 1 (according DIN EN 60664-1)
There is either no pollution or it occurs only dry, non-conductive pollution. The pollution has no negative impact.
**) The specification of the IP protection refers to the conditions mentioned in certification of the fan. The above
mentioned short description of the protection scope is not final. For detailed information of the respective protection
scope and definitions, see certification as well as DIN EN 60529 (protection by housings) and ISO 20653 (for vehicles)
with the letter K.
Short description of the IP-protection type:
Solid particle Protection: Protected against solid particles with a diameter of 12.5 mm and larger.
Protection against deliberate contact: Protected against contact to hazardous parts with a finger.
Protection against water: No protection.