Datasheet
Product Data Sheet AC 8300/19H
2/28/2019 page 5 of 12
3.2 Electrical Operating Data
Features Condition Symbol
Values
Voltage range
Tolerance
U
100 V
265 V
Nominal voltage U
N
115 230 V
Frequency f 50 Hz / 60 Hz
Power consumption
Tolerance
∆p = 0 P
7,5 W
+- 20 %
Current
consumption
130 mA 115 mA 58 mA 53 mA
Tolerance
∆p = 0 I
RMS
+- 20 % +- 25 % +- 20 % +- 25 %
Speed 5.000 1/min
+- 10 %
Tolerance
∆p = 0 n
3.3 Electrical Interface - Output
External voltage supply for input and output signals must be SELV conform.