Datasheet

Product Data Sheet AC 100 NR
2/28/2019 page 9 of 10
5 Safety
5.1 Electrical Safety
A verification of thermal conditions (normal and abnormal operation) as well as the protection against electric shock,
ingress of solid foreign objects and water has to be done in conjuction with the appliance.
Test voltage HV type test 1500 V
Unit test voltage VAC
Time type test HV 1 min
Insulation resistance RI > 50 MOhm
Protection class built-in fan
5.2 Approval Tests
CE EC Declaration of Conformity Yes
EAC Eurasian Conformity Yes
UL Underwriters Laboratories No
VDE Association for Electrical, Electronic and
Information Technologies
Yes / Approval acc. to EN 60335 (VDE 0700) - Safety for
household and similar electrical appliances
CSA Canadian Standards Association No
CCC
China Compulsory Certification
Not applicable
According to the guidelines on the application of Directive 2006/95/EC, chapter III: Scope of the "low voltage" directive,
paragraph: Are "components" included in the scope? the following has to be applied:
However, some types of electrical devices, designed and manufactured for being uses as basic components to be
incorporated into other electrical equipment, are such that their safety to a very large extent depends on how they are
integrated into the final product and the overall characteristics of the final product. These basic components include
electronic and certain other components.
Taking into account these objectives of the "Low Voltage" Directive, such basic components, the safety of which can
only, to a very large extend, be assessed taking into account, how
they are incorporated and for which a risk
assessment cannot be undertaken, then they are not
covered as such by the Directive. In particular, they must not be
CE marked unless covered by other Community legislation that requires CE marking.
6 Reliability
6.1 General
Life expectancy L10 at TU = 40 °C 70.000 h
Life expectancy L10 at TU max. 40.000 h
Life expectancy L10 acc. to IPC 9591 at TU = 40 °C 117. 500 h