Datasheet

Product Data Sheet 8452/2N
02/01/2019 page 5 of 12
3 Operating Data
3.1 Electrical Operating Data
Measurement
conditions:
Normal air density = 1,2 kg/m3; Temperature 23°C +/ - 3°C; Motor axis horizontal; warm-up
time before measuring 5 minutes (unless otherwise specified). In the intake and outlet area
should not be any solid obstruction within 0,5 m.
∆p = 0:
corresp. to free air flow (see chapter aerodynamics)
I:
corresp. to arithm. mean current value
Features Condition Symbol Values
Voltage range U 8,0 V 15,0 V
Nominal voltage U
N
12,0 V
Power consumption 0,8 W 1,9 W 3 W
+- 17,5 % +- 12,5 % +- 15,0 %
Tolerance
∆p = 0
0010
P
Current consumption 98 mA 160 mA 204 mA
+- 17,5 % +- 12,5 % +- 15,0 %
Tolerance
∆p = 0
0010
I
Speed 2.530 1/min 3.600 1/min 4.240 1/min
+- 12,5 % +- 7,5 % +- 10,0 %
Tolerance
∆p = 0
0010
n
Starting current
consumption
< 500 mA