Datasheet
Product Data Sheet 8414 NGR
07/10/2017 page 4 of 9
3 Operating Data
3.1 Electrical Operating Data
Measurement
conditions:
Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C; Motor axis horizontal; warm-up
time before measuring 5 minutes (unless otherwise specified). In the intake and outlet area
should not be any solid obstruction within 0,5 m.
∆p = 0:
corresp. to free air flow (see chapter aerodynamics)
I:
corresp. to arithm. mean current value
Features
Condition
Symbol
Values
Voltage range U 18,0 V 28,0 V
Nominal voltage U
N
24,0 V
Power consumption
∆p = 0
0010
P
1,3 W 2,0 W 3,0 W
Tolerance
+- 17,5 % +- 12,5 % +- 15,0 %
Current consumption
∆p = 0
0010
I
70 mA 85 mA 110 mA
Tolerance
+- 17,5 % +- 12,5 % +- 15,0 %
Speed
∆p = 0
0010
n
2.480 1/min 3.100 1/min 3.750 1/min
Tolerance
+- 12,5 % +- 7,5 % +- 10,0 %
Starting current
consumption
254 mA
3.2 Electrical Features
Electronic function None
Reversed polarity protection Rectifying diode
Max. residual current at U
N
I
F
<= 5 uA
Locked rotor protection Auto restart
Locked rotor current at U
N
I
block
approx. 254 mA
Clock signal at locked rotor
t
3
/ t
4
typical: 0,2 s / 1,1 s