Datasheet

Product Data Sheet 8314 NH
07/26/2018 page 5 of 10
3 Operating Data
3.1 Electrical Operating Data
Measurement
conditions:
Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C; Motor axis horizontal; warm-up
time before measuring 5 minutes (unless otherwise specified). In the intake and outlet area
should not be any solid obstruction within 0,5 m.
p = 0:
corresp. to free air flow (see chapter aerodynamics)
I:
corresp. to arithm. mean current value
Features
Condition
Symbol
Values
Voltage range
U
12 V
28 V
Nominal voltage
U
N
24 V
Power consumption
p = 0
0010
P
1 W
3,6 W
5 W
Tolerance
+- 17,5 %
+- 12,5 %
+- 15 %
Current consumption
p = 0
0010
I
75 mA
150 mA
180 mA
Tolerance
+- 17,5 %
+- 12,5 %
+- 15 %
Speed
p = 0
0010
n
2.700 1/min
5.300 1/min
6.100 1/min
Tolerance
+- 12,5 %
+- 7,5 %
+- 10 %
Starting current
consumption
1.100 mA
3.2 Electrical Features
Electronic function
None
Reversed polarity protection
Rectifying diode
Max. residual current at U
N
I
F
<= 500 uA
Locked rotor protection
Auto restart
Locked rotor current at U
N
I
block
approx. 1.100 mA
Clock signal at locked rotor
t
3
/ t
4
typical: 0,16 s / 11,8 s