Datasheet
Product Data Sheet 8214 J/2H3PU-216
01/31/2019 page 11 of 13
Protection against water: The fan test according to IP68 (Based on IEC 60529), is conducted in non-operating mode.
The fan is tested by a complete immersion in water for a period of 2h at a water-level of 1,2m. Electrical connections
are not immersed since they are customer specific.
Please require severity levels and specification parameters from the responsible development departments.