Datasheet
Product Data Sheet 8214J/2H3P
02/01/2019 page 8 of 12
3.5 Aerodynamics
Measurement
conditions:
Measured with a double chamber intake rig acc. to DIN EN ISO 5801.
Normal air density = 1,2 kg/m3; Temperature 23°C +/ - 3°C;
In the intake and outlet area should not be any solid obstruction within 0,5 m. Motor shaft
horizontal.
The information is only valid under the specified test conditions and may be changed by the
installation conditions. If there are deviations from the standard test conditions, the
characteristic values must be checked under the installed conditions.
a.) Operation condition:
12.000 1/min at free air
flow
PWM 100 %; PWM min.: 90 %; f: 1 kHz PWM max.:100 %; f: 5 kHz
Max. free-air flow (∆p = 0 /
= max.) 190 m3/h
Max. static pressure (∆p = max. /
=0) 490 Pa