Datasheet

Product Data Sheet 6448 I
02/02/2019 page 5 of 10
3.2 Electrical Operating Data
Measurement
conditions:
Normal air density = 1,2 kg/m3; Temperature 23°C +/ - 3°C; Motor axis horizontal; warm-up
time before measuring 5 minutes (unless otherwise specified). In the intake and outlet area
should not be any solid obstruction within 0,5 m.
p = 0:
corresp. to free air flow (see chapter aerodynamics)
I:
corresp. to arithm. mean current value
Name Condition
TU 0001 TU: >= 50 °C
NTC 0001
Tu >= 50 °C or broken Sensor.
Features Condition Symbol Values
Voltage range U 28 V 60 V
Nominal voltage U
N
48 V
Power consumption 4,5 W 17 W 21,0 W
+- 15 % +- 15 % +- 15 %
Tolerance
p = 0
TU / NTC
0010
P
Current consumption 160 mA 355 mA 350 mA
+- 15 % +- 15 % +- 15 %
Tolerance
p = 0
TU / NTC
0010
I
Speed 2.150 1/min 3.400 1/min 3.820 1/min
+- 10 % +- 8 % +- 10 %
Tolerance
p = 0
TU / NTC
0010
n
Starting current
consumption
<= 1.000 mA
3.3 Electrical Features
Electronic function Speed-Controlled
Reversed polarity protection Rectifying diode
Max. residual current at U
N
I
F
<= 10 mA
Locked rotor protection Auto restart
Locked rotor current at U
N
I
block
approx. 800 mA
Clock signal at locked rotor
t
3
/ t
4
typical: 0,5 s / 5,0 s