Datasheet
Product Data Sheet 6318 N/2H3PU
02/01/2019 page 6 of 14
7% - 10 % PWM: 500 1/min (corresp. to min fan speed)
10% - 90% PWM: Linear increasing curve
90% - 100% PWM: 5.000 1/min (corresp. to max fan speed)
Transistor Requirements:
VCE max. >= 12V
Isink max > 5mA
VCEsat < 0,15V
3.2 Electrical Operating Data
Measurement
conditions:
Normal air density = 1,2 kg/m3; Temperature 23°C +/ - 3°C; Motor axis horizontal; warm-up
time before measuring 5 minutes (unless otherwise specified). In the intake and outlet area
should not be any solid obstruction within 0,5 m.
∆p = 0:
corresp. to free air flow (see chapter aerodynamics)
I:
corresp. to arithm. mean current value
Name Condition
PWM 0001 PWM: 95 %; f: 2 kHz
>90% PWM; f = 2 kHz or broken lead wire (open control input)
Features Condition Symbol Values
Voltage range U 36 V 60 V
Nominal voltage U
N
48 V
Power consumption 37 W 58 W 60 W
+- 10 % +- 10 % +- 10 %
Tolerance
∆p = 0
PWM 0010
P
Current consumption 1.030 mA 1.200 mA 1.000 mA
+- 10 % +- 10 % +- 10 %
Tolerance
∆p = 0
PWM 0010
I
Speed 4.300 1/min 5.000 1/min 5.000 1/min
+- 10 % +- 5 % +- 5 %
Tolerance
∆p = 0
PWM 0010
n